Showing all 4 results
-
Acrylic Flow Meter > SF100
Service:Liquid & Oil Flow Range: 0.6~60 LPM Wetted Parts Material:Body- Acrylic plastic; O-ring: Viton; Float- magnet cover with PPS plastic; Connection- SS316; Spring- SS316 Connection Size: ⅜", ½", ¾"NPT female availabl...
Service:Liquid & Oil Flow Range: 0.6~60 LPM Wetted Parts Material:Body- Acrylic plastic; O-ring: Viton; Float- magnet cover with PPS plastic; Connection- SS316; Spring- SS316 Connection Size: ⅜", ½", ¾"NPT female available Mounting:Vertical and Horizontal available, various flow directions Temperature & Pressure Limits:150psig (10bar) @100ºF (38ºC) Temperature Limit:-24ºC~+54ºC Accuracy: ±5% full scale Alarm Switch:One or Two setting points, form A N.O. type bistable reed switch Switch Rating:AC 125V 0.5A / DC 100V 10W / Max. DC 250V<40mA Weight: 0.45~0.5 kg (Contact setting point should be within 10% to 80% of F.S.)...
Read More>>
- Service:Liquid & Oil
- Flow Range: 0.6~60 LPM
- Wetted Parts Material:Body- Acrylic plastic; O-ring: Viton;
- Float- magnet cover with PPS plastic; Connection- SS316;
Spring- SS316 - Connection Size: ⅜”, ½”, ¾”NPT female available
- Mounting:Vertical and Horizontal available, various flow directions
- Temperature & Pressure Limits:150psig (10bar) @100ºF (38ºC)
- Temperature Limit:-24ºC~+54ºC
- Accuracy: ±5% full scale
- Alarm Switch:One or Two setting points, form A N.O. type bistable reed switch
- Switch Rating:AC 125V 0.5A / DC 100V 10W / Max. DC 250V<40mA
- Weight: 0.45~0.5 kg
- (Contact setting point should be within 10% to 80% of F.S.)
-
Paddle Flow Switch > FS20
Size:from ½" to 1" Service:For "Non-Corrosive" liquid fluid available(*see Note) Material:Wetted parts 316 stainless steel Temperature Limit:-20ºC~150ºC Pressure Limit:7.0 MPa (70 kg/cm²) Enclosure Housing:FS20R & FS20 Di...
Size:from ½" to 1" Service:For "Non-Corrosive" liquid fluid available(*see Note) Material:Wetted parts 316 stainless steel Temperature Limit:-20ºC~150ºC Pressure Limit:7.0 MPa (70 kg/cm²) Enclosure Housing:FS20R & FS20 Din- Weather proof type; FS20X- Explosion proof type Switch Function:SPDT micro switch Switch Rating:3A/250VAC, 3A/30VDC, 0.4A/125VDC Conduit Connection:Female ½", ¾" G, NPT, and M20xP1.5 or M25xP1.5 available *NOTE 1.: In general, we DON'T recommend using FS20 for the seawater application! But, if it is necessary, please let us know, we can customize the speical magnet with lining to match up! *NOTE 2.: If using the FS20 for the Emergency Shower, please contact with the manufacturer at the first!!...
Read More>>
- Size:from ½” to 1″
- Service:For “Non-Corrosive” liquid fluid available(*see Note)
- Material:Wetted parts 316 stainless steel
- Temperature Limit:-20ºC~150ºC
- Pressure Limit:7.0 MPa (70 kg/cm²)
- Enclosure Housing:FS20R & FS20 Din- Weather proof type; FS20X- Explosion proof type
- Switch Function:SPDT micro switch
- Switch Rating:3A/250VAC, 3A/30VDC, 0.4A/125VDC
- Conduit Connection:Female ½”, ¾” G, NPT, and M20xP1.5 or M25xP1.5 available
- *NOTE 1.:
In general, we DON’T recommend using FS20 for the seawater application!
But, if it is necessary, please let us know, we can customize the speical
magnet with lining to match up!
*NOTE 2.:
If using the FS20 for the Emergency Shower, please contact with the manufacturer
at the first!!
-
Variable Area Type Flow Meter > N_Type
Measuring the Flow Rate for: Gases & Liquid Chemical process system Water treatment system Industrial flow system Service Condition: Viscosity: ≤3 cP Max. working temperature: Metal 100º...
Measuring the Flow Rate for: Gases & Liquid Chemical process system Water treatment system Industrial flow system Service Condition: Viscosity: ≤3 cP Max. working temperature: Metal 100ºC; Plastic 60ºC Max. working pressure: Body material: NS- 15 kg/cm²; NI- 15 kg/cm², NV- 6 kg/cm² Glass tube: 6 kg/cm² for 10A~50A; 5 kg/cm² for 65A~80A; 4 kg/cm² for 100A~150A PC tube: 10 kg/cm², Instant pressure: 15 kg/cm² Alarm Switch Available (N.O.) Switch rating:AC 125V 0.5A / DC 100V 10W / Max. DC 250V <40mA Accuracy:±2.5% F.S....
Read More>>
-
Measuring the Flow Rate for:
-
Gases & Liquid
-
Chemical process system
-
Water treatment system
-
Industrial flow system
-
-
Service Condition:
-
Viscosity: ≤3 cP
-
Max. working temperature: Metal 100ºC; Plastic 60ºC
-
Max. working pressure:
-
Body material: NS- 15 kg/cm²; NI- 15 kg/cm², NV- 6 kg/cm²
-
Glass tube: 6 kg/cm² for 10A~50A; 5 kg/cm² for 65A~80A; 4 kg/cm² for 100A~150A
-
PC tube: 10 kg/cm², Instant pressure: 15 kg/cm²
-
-
Alarm Switch Available (N.O.)
-
Switch rating:AC 125V 0.5A / DC 100V 10W / Max. DC 250V <40mA
-
Accuracy:±2.5% F.S.
-
-
Variable Area Type Flow Meter > P_Type
Measuring the Flow Rate for: - Chemical process system - Water treatment system - Industrial flow system Service Condition: -...
Measuring the Flow Rate for: - Chemical process system - Water treatment system - Industrial flow system Service Condition: - Viscosity: ≤3 cP - Max. working temperature: Metal 100°C; Plastic 60°C - Max. working pressure: - Body material: PS, PI- 15 kg/cm²; Plastic- 6 kg/cm² - Glass tube: Borosilicate glass 6 kg/cm², - PC tube: 10 kg/cm², Instant pressure: 15 kg/cm² Alarm Switch Available (N.O.) Switch rating:AC 125V 0.5A / DC 100V 10W / Max. DC 250V <40mA Accuracy:±2.5% F.S....
Read More>>
-
Measuring the Flow Rate for:
– Chemical process system– Water treatment system– Industrial flow system-
Service Condition:
– Viscosity: ≤3 cP– Max. working temperature: Metal 100°C; Plastic 60°C– Max. working pressure:– Body material: PS, PI- 15 kg/cm²; Plastic- 6 kg/cm²– Glass tube: Borosilicate glass 6 kg/cm²,– PC tube: 10 kg/cm², Instant pressure: 15 kg/cm²-
Alarm Switch Available (N.O.)
-
Switch rating:AC 125V 0.5A / DC 100V 10W / Max. DC 250V <40mA
-
Accuracy:±2.5% F.S.
-